Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes

dc.contributor.authorYılmaz, Ebru
dc.contributor.authorErok, Berrin
dc.contributor.authorAtca, Ali Önder
dc.date.accessioned2021-05-15T11:34:08Z
dc.date.available2021-05-15T11:34:08Z
dc.date.issued2019
dc.departmentTıp Fakültesi, Radyoloji Anabilim Dalıen_US
dc.description.abstractPurpose: We aimed to determine the contribution of the apparent diffusion coefficient (ADC) value in the detection of axillary lymph node metastasis. Material and methods: Breast magnetic resonance of 58 patients, performed in the radiology clinic of our hospital between 2015 and 2017 were examined retrospectively, and 43 lymph nodes in 43 patients were included in the study. They were evaluated morphologically on T1W and T2W sequences, and the lymph nodes showing rounded shape, focal or diffuse cortical thickness of more than 3 mm, and partial or total effacement of fatty hilum were included in the study. Subsequently, their ADC values were measured. Results: There were 43 lymph nodes, 20 of which were malignant and 23 of which were benign. While the mean ADC value of malignant axillary lymph nodes was 0.749 10(-3) min(2)/s (0.48-1.342), it was 0.982 10(-3) mm(2)/s (0.552-1.986) for benign lymph nodes. When the ADC cut-off value was taken as <= 0.753 x 10(-3) mm(2)/s, its discrimination power between benign and malignant axillary lymph nodes was as follows: sensitivity - 60%; specificity - 91.3%; accuracy - 76.7%; positive predictive value - 85.7%; and negative predictive value - 72.4%. Conclusions: There was no significant difference between mean ADC value of 12 lymphadenopathies (LAP) associated with inflammatory breast diseases (granulomatous mastitis and acute suppurative mastitis) and mean ADC value of metastatic lymph nodes. However, the ADC value of lymph nodes showing thickened cortex due to systemic inflammatory diseases was over 1, and there was a statistically significant difference when compared with metastatic lymph nodes.en_US
dc.identifier.doi10.5114/pjr.2019.92315
dc.identifier.endpageE597en_US
dc.identifier.issn0137-7183
dc.identifier.issn1899-0967
dc.identifier.pmid32082458
dc.identifier.scopus2-s2.0-85096443955
dc.identifier.scopusqualityQ3
dc.identifier.startpageE592en_US
dc.identifier.urihttps://doi.org/10.5114/pjr.2019.92315
dc.identifier.urihttps://hdl.handle.net/20.500.12939/284
dc.identifier.volume84en_US
dc.identifier.wosWOS:000512542800001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorAtca, Ali Önder
dc.language.isoen
dc.publisherInt Scientific Information Incen_US
dc.relation.ispartofPolish Journal of Radiology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAxillary LAPen_US
dc.subjectBreast Canceren_US
dc.subjectDiffusion-Weighted Imaging (DWI)en_US
dc.subjectApparent Diffusion Coefficient (ADC)en_US
dc.titleMeasurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Measurement of apparent diffusion coefficient in discrimination of benign and malignant axillary lymph nodes .pdf
Boyut:
423.72 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/ Full Text