A potential novel technique for measurement of pulp volume on periapical radiography: A pilot study

dc.contributor.authorŞatır, Samet
dc.contributor.authorÖzel, Şelale
dc.contributor.authorOrhan, Kaan
dc.date.accessioned2024-03-30T08:50:23Z
dc.date.available2024-03-30T08:50:23Z
dc.date.issued2024en_US
dc.departmentFakülteler, Diş Hekimliği Fakültesi, Ağız, Diş, Çene Radyolojisi Ana Bilim Dalıen_US
dc.description.abstractPulp volume can be assessed during dental treatment. Three-dimensional imaging techniques are not routinely used for this purpose because of high radiation doses. This study aimed to develop a novel method to measure pulp volume using periapical radiography. In this study, cone-beam computed tomography (CBCT) was used as a reference method. Periapical radiography and CBCTs obtained from the same patients (n = 32) were recorded. Pulp volume was determined by observing the density differences between the pulp and peripheral structures using ImageJ. A method of graph and volume calculation was developed for each tooth. The Shapiro-Wilk test and Mann-Whitney U test were used to show normality and non-normal distributions. The Bland-Altman plot was used to show the scattering of the mean versus difference values of the measurements of the two methods used to calculate the pulp volume. Normality was evaluated using the Shapiro-Wilk test. CBCT measurements are normally distributed (p = 0.307), while ImageJ is not normally distributed (p = 0.027). Therefore, the mean difference between the two groups was analyzed using the nonparametric Mann-Whitney U test. There was a statistically significant difference between the CBCT and ImageJ measurements (p = 0.01). According to Spearman's correlation analysis, the results obtained from the novel method were moderately correlated with those obtained from the reference method (r = 0.444). The results of this study indicated that a novel method-based Java software can be used to calculate pulp volume using low-dose radiation containing periapical radiography.en_US
dc.identifier.citationŞatır, S., Özel, Ş., Orhan, K. (2024). A potential novel technique for measurement of pulp volume on periapical radiography: A pilot study. The Kaohsiung Journal of Medical Sciences, 40(5), 499-505.en_US
dc.identifier.endpage505en_US
dc.identifier.issn1607-551X
dc.identifier.issn2410-8650
dc.identifier.issue5en_US
dc.identifier.scopus2-s2.0-85187179451
dc.identifier.scopusqualityQ1
dc.identifier.startpage499en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12939/4644
dc.identifier.volume40en_US
dc.identifier.wosWOS:001180443100001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorÖzel, Şelale
dc.language.isoen
dc.relation.ispartofThe Kaohsiung Journal of Medical Sciences
dc.relation.isversionof10.1002/kjm2.12814en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCBCTen_US
dc.subjectImageJen_US
dc.subjectPeriapical radiographyen_US
dc.subjectPulp volumeen_US
dc.titleA potential novel technique for measurement of pulp volume on periapical radiography: A pilot study
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
The Kaohsiung J of Med Scie - 2024 - Şatır - A potential novel technique for measurement of pulp volume on periapical.pdf
Boyut:
1.59 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: