Development of a paper-type tyrosinase biosensor for detection of phenolic compounds
dc.contributor.author | Şenyurt, Özge | |
dc.contributor.author | Eyidoğan, Füsun | |
dc.contributor.author | Yılmaz, Remziye | |
dc.contributor.author | Öz, M. Tufan | |
dc.contributor.author | Özalp, V. Cengiz | |
dc.contributor.author | Arıca, Yakup | |
dc.contributor.author | Öktem, Huseyin A. | |
dc.date.accessioned | 2021-05-15T12:40:38Z | |
dc.date.available | 2021-05-15T12:40:38Z | |
dc.date.issued | 2015 | |
dc.department | Tıp Fakültesi, Biyokimya Anabilim Dalı | en_US |
dc.description | Ozalp, Veli Cengiz/0000-0002-7659-5990; Oz, Mehmet Tufan/0000-0002-0042-2671 | |
dc.description.abstract | A low-cost, portable, and disposable paper-type tyrosinase biosensor was developed for determination of phenolic compounds, using a paper-strip absorption method. Tyrosinase and a chromophore (3-methyl-2-benzothiazolinone hydrazone) were immobilized on paper strips to manufacture the biosensor, which was tested on a nontoxic substrate (l-dopamine). The biosensor was responsive to phenolic compounds such as 4-chlorophenol, catechol, m-cresol, and p-cresol. The sensor showed stability for 70days. The developed biosensor can be used for remote on-site qualitative monitoring of phenolic compounds in wastewater samples. | en_US |
dc.identifier.doi | 10.1002/bab.1246 | |
dc.identifier.endpage | 136 | en_US |
dc.identifier.issn | 0885-4513 | |
dc.identifier.issn | 1470-8744 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 24847915 | |
dc.identifier.scopus | 2-s2.0-84922929301 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 132 | en_US |
dc.identifier.uri | https://doi.org/10.1002/bab.1246 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12939/639 | |
dc.identifier.volume | 62 | en_US |
dc.identifier.wos | WOS:000350114600019 | |
dc.identifier.wosquality | Q2 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.institutionauthor | Özalp, V. Cengiz | |
dc.language.iso | en | |
dc.publisher | Wiley-Blackwell | en_US |
dc.relation.ispartof | Biotechnology and Applied Biochemistry | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | 4-Chlorophenol | en_US |
dc.subject | Catechol | en_US |
dc.subject | Cresol | en_US |
dc.subject | l-Dopamine | en_US |
dc.subject | Paper Strip | en_US |
dc.subject | Phenol | en_US |
dc.title | Development of a paper-type tyrosinase biosensor for detection of phenolic compounds | |
dc.type | Article |