Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: A finite element analysis

[ X ]

Tarih

2021

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Springer Heidelberg

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

The purpose of this study was to determine the effects of prosthetic materials and crown/implant (C/I) ratio on short implants with a marginal bone resorption. Three-dimensional finite element analysis was used to simulate stress distribution under static loading in non-resorption and resorption scenarios (3-mm vertical bone loss) in implants restored with single crowns and C/I ratios of 1:1, 1.5:1, and 2:1 were evaluated. Different crown materials were used: porcelain-fused to metal, porcelain-fused to zirconia, monolithic zirconia, and zirconia-based crown veneered with indirect composite resin. The C/I ratio, the peri-implant bone resorption, and the loading conditions were the key factors affecting the generated stress in short implants. In non-resorption models, von Mises stress ranged between 50 and 105 MPa whereas in resorption models, the values ranged from 168 to 322 MPa, both increasing with the higher C/I ratio under oblique forces. Under axial loading, the C/I ratio did not influence the stress values as the presence of resorption was the only parameter increasing, 57 MPa for the non-resorption models and 101 MPa for the resorption models, respectively. Preference of a prosthetic material was ineffective on the distribution of stress in the bone and implant structure under static loading in any models. The peri-implant bone resorption and a higher C/I ratio in short implants increase the stress values under both axial and oblique forces, whereas the crown material does not influence stress distribution in the surrounding bone and implant structure.

Açıklama

Anahtar Kelimeler

Dental Implants, Implant Prosthesis, Crown Restoration, Bone Resorption, Finite Element Analysis

Kaynak

Medical & Biological Engineering & Computing

WoS Q Değeri

Q2

Scopus Q Değeri

Q2

Cilt

Sayı

Künye